2025-01-24
厚度 R20 R20 0.8 0.9 1 1.12 1.25 1.4 1.6 1.8 2 2.24 宽度 R20 R40 0.85 0.95 1.06 1.18 1.32 1.5 1.7 1.9 2.12 2.36 2 1.463 1.545 1.626 1.706 1.785 1.905 2.025 2.145 2.285 2.425 2.585 2.12 1.559 1.734 1.905 2.16 2.435 2.753 2.24 1.655 1.749 1.842 1.934 2.025 2.159 2.294 2.428 2.585 2.742 2.921 3.145 3.369 2.36 1.751 1.95 2.145 2.428 2.735 3.089 3.561 2.5 1.863 1.97 2.076 2.181 2.285 2.435 2.585 2.735 2.91
导线规格及面积 规格3.153.353.553.754.004.254.504.755.005.305.606.006.306.707.107.50 1.123.3133.5373.7633.9854.2654.5454.8255.1055.3855.7216.0576.5056.8417.2897.7378.185 1.183.5023.7383.9744.2104.5054.805.0955.3905.6856.0396.3936.8657.2197.6918.1638.635 1.253.7233.9734.2234.4734.7855.0985.4105.7236.0356.4106.7857.2857.6608.1608.6609.160 1.3
丝包纸包扁铜铝线规格及面积 2 ————————————————————————————————作者: ————————————————————————————————日期: 3/7 导线规格及面积 规格3.153.353.553.754.004.254.504.755.005.305.606.006.306.707.107.50 1.123.3133.5373.7633.9854.2654.5454.8255.1055.3855.7216.0576.5056.8417.2897.7378.185 1.183.5023.7383.9744.2104.5054.805.0955.3905.6856.0396.3936.8657.2197.6918.1638.635 1.253.
铜线截面积(平方):1.0,1.5,2.5,4,6,10, 聚氯乙烯绝缘电线穿塑料管时(三根并排穿),安全载流量为11,15,21,28, 36,49。单位:安。(按上面顺序) 穿铁管时比穿塑料管的大三安左右! 如果是塑料绝缘电线的话又和这不一样啦!只比这种再大点!但一般情况下, 塑料绝缘电线很少用,通用的是聚氯乙烯绝缘电线! 10下五,100上二,16、25四,35、50三,70、95两倍半。 穿管、温度八、九折,裸线加一半。铜线升级算。 口诀中的阿拉伯数字与倍数的排列关系如下: 对于1.5、2.5、4、6、10mm2的导线可将其截面积数乘以5倍。 对于16、25mm2的导线可将其截面积数乘以4倍。 对于35、50mm2的导线可将其截面积数乘以3倍。 对于70、95mm2的导线可将其截面积数乘以2.5倍。 对于120、150、185mm2的导线可将其截面积数乘以
电缆规格直径截面积填充率20%填充率30%填充率40% 2.50.00.00.00.00.0 40.00.00.00.00.0 60.00.00.00.00.0 100.00.00.00.00.0 160.00.00.00.00.0 2514.7169.6848.2565.4424.1 3515.7193.5967.5645.0483.7 5017.2232.21161.2774.1580.6 7019.1286.41431.9954.6715.9 9520.7336.41681.81121.2840.9 12022.3390.41951.91301.2975.9 15024.3463.52317.71545.11158.8 18526.4547.1
铜芯线截面积换直径 1平方毫米的电线直径是1.13毫米。 1.5平方毫米的电线直径是1.33毫米。 2.5平方毫米的电线直径是1.76毫米。 4平方毫米的电线直径是2.24毫米。 6平方毫米的电线直径是2.73毫米。 10平方毫米的电线直径是3.56毫米 16平方毫米的电线直径是4.5毫米 25平方毫米的电线直径是5.64毫米 35平方毫米的电线直径是6.68毫米 50平方毫米的电线直径是7.98毫米 铜芯线载流量 1mm15a 1.518a 2.526a 438a 644a 1068a 1680a 25109a 35125a 50163a 70202a 95243a 120285a 150320a
电线标 称截面 积 (mm2) 1.52.54610162535507095120150185240300400 线芯直 径(mm) 及根数 1.131.782.252.76 1.35 ×7 1.70 ×7 2.14 ×7 2.52 ×7 1.78 ×19 2.14 ×19 2.52 ×19 2.03 ×37 2.25 ×37 2.52 ×37 绝缘层 厚度 (mm) 0.70.80.80.81.01.01.21.21.41.41.61.61.82.02.22.42.6
类型bvbvvzrbvnhbv类型vvvv22vvvv22类型yjvyjv22yjvyjv22 2.51125.614154x2.513913.34x2.5132.7176.61315 41433.21819.44x418629315.519.34x4154.92011416 61839.623274x624433017.620.54x6179240.415.517.5 103460.83940.44x1030839819.822.54x10240.431417.520 164872.45058.34x1639451922.425.74x163143802022 2572103.87977.64x25476684
导线,指的是用作电缆的材料,工业上也指电线。一般由铜或铝制成,铜 导线或者铝导线,也有用银线所制(导电、热性好),用来疏导电流或者 是导热。 1平方的导线最大能过多少安的电流,多大的功率? 例如2.5平方的电线,工程施工中怎样算要用多大的电线? ①对于1.5、2.5、4、6、10平方的导线可将其截面积数乘以5倍。 ②对于16、25平方的导线可将其截面积数乘以4倍。 ③对于35、50平方的导线可将其截面积数乘以3倍。 ④对于70、95平方的导线可将其截面积数乘以2.5倍。 ⑤对于120、150、185平方的导线可将其截面积数乘以2倍。 在工作温度30℃,长期连续90%负载下的载流量如下: 1.5平方毫米――18a 2.5平方毫米――26a 4平方毫米――26a 6平方毫米――47a 10平方毫米――6
电缆规格直径截面积填充率20%填充率30%填充率40% 2.56.230.1150.4100.375.2 46.734.8174.1116.187.0 67.240.4201.8134.5100.9 108.252.9264.6176.4132.3 169.266.6332.9222.0166.5 2510.892.1460.4306.9230.2 3511.8109.9549.3366.2274.6 5013.3139.7698.5465.7349.2 7015.3182.6912.8608.5456.4 9517.1228.51142.3761.6571.2 12018.7273.61368.1912.1684.1 15020.9342.91714.51
电线截面积电流对照表 对于1.5、2.5、4、6、10mm2的导线可将其截面积数乘以5倍。 对于16、25mm2的导线可将其截面积数乘以4倍。 对于35、50mm2的导线可将其截面积数乘以3倍。 对于70、95mm2的导线可将其截面积数乘以2.5倍。 对于120、150、185mm2的导线可将其截面积数乘以2倍 工作温度30℃,长期连续90%负载下的载流量如下: 1.5平方毫米――18a 2.5平方毫米――26a 4平方毫米――26a 6平方毫米――47a 10平方毫米――66a 16平方毫米――92a 25平方毫米――120a 35平方毫米――150a 功率p=电压u×电流i=220伏×18安=3960瓦 标gb4706.1-1992/1998规定的电线负载电流值(部分) 横截面积允许长期
类型bvbvvzrbvnhbv类型vvvv22vvvv22类型yjvyjv22yjvyjv22 2.51125.614154x2.513913.34x2.5132.7176.61315 41433.21819.44x418629315.519.34x4154.92011416 61839.623274x624433017.620.54x6179240.415.517.5 103460.83940.44x1030839819.822.54x10240.431417.520 164872.45058.34x1639451922.425.74x163143802022 2572103.87977.64x25476684
1、常用的电线、电缆按用途分有哪些种类? 答:按用途可分为裸导线、绝缘电线、耐热电线、屏蔽电线、电力电缆、控制电缆、通信电 缆、射频电缆等。 2、绝缘电线有哪几种? 答:常有的绝缘电线有以下几种:聚氯乙烯绝缘电线、聚氯乙烯绝缘软线、丁腈聚氯乙烯混 合物绝缘软线、橡皮绝缘电线、农用地下直埋铝芯塑料绝缘电线、橡皮绝缘棉纱纺织软线、 聚氯乙烯绝缘尼龙护套电线、电力和照明用聚氯乙烯绝缘软线等。 3、电缆桥架适合于何种场合? 答:电缆桥架适用于一般工矿企业室内外架空敷设电力电缆、控制电缆,亦可用于电信、广 播电视等部门在室内外架设。 4、电缆附件有哪些? 答:常用的电附件有电缆终端接线盒、电缆中间接线盒、连接管及接线端子、钢板接线槽、 电缆桥架等。 5、什么叫电缆中间接头? 答:连接电缆与电缆的导体、绝缘屏蔽层和保护层,以使电缆线路连接的装置,称为电缆中 间接头。 6、什么叫电气主接线? 答:电
电缆规格直径截面积填充率20%填充率30%填充率40% 2.56.230.1150.4100.375.2 46.734.8174.1116.187.0 67.240.4201.8134.5100.9 108.252.9264.6176.4132.3 169.266.6332.9222.0166.5 2510.892.1460.4306.9230.2 3511.8109.9549.3366.2274.6 5013.3139.7698.5465.7349.2 7015.3182.6912.8608.5456.4 9517.1228.51142.3761.6571.2 12018.7273.61368.1912.1684.1 15020.9342.91714.51
电缆规格直径截面积填充率20%填充率30%填充率40% 2.56.230.1150.4100.375.2 46.734.8174.1116.187.0 67.240.4201.8134.5100.9 108.252.9264.6176.4132.3 169.266.6332.9222.0166.5 2510.892.1460.4306.9230.2 3511.8109.9549.3366.2274.6 5013.3139.7698.5465.7349.2 7015.3182.6912.8608.5456.4 9517.1228.51142.3761.6571.2 12018.7273.61368.1912.1684.1 15020.9342.91714.51
标称截面积mm2参考外径/mm 载流量推荐值/a成品参考考质量 /(kg/km)空气中敷设埋地敷设 铜芯铝芯铜芯铝芯铜芯铝芯 1.56.824-33-61- 2.57.2322544357459 4.08.14233574510076 6.08.65442735712487 1010.0755710178183119 1611.09977133103251149 2512.7132103175136367206 3513.9162125210163475252 5015.6194150250194618316 7017.4246189314241840403 9519.7298231375291
电流与电线截面积的关系 电流与电线截面积的关系绝缘导线载流量估算 一.铝芯绝缘导线载流量与截面的倍数关系 截面:11.52.54610162535507095120 倍数:999876543.5332.52.5 电流:9142332486090100123150210238300 口诀一: 十下五;百上二;二五三五四三界; 七零九五两倍半;穿管温度八九折; 铜线升级算;裸线加一半 说明: 十下五就是十以下乘以五; 百上二就是百以上乘以二; 二五三五四三界就是二五乘以四,三五乘以三; 七零九五两倍半就是七零和九五线都乘以二点五; 穿管温度八九折就是随着温度的变化而变化,在算好的安全电流数上乘以零点 八或零点九; 铜线升级算就是在同截面铝芯线的
类型bvbvvzrbvnhbv类型vvvv22vvvv22类型yjvyjv22yjvyjv22 2.51125.614154x2.513913.34x2.5132.7176.61315 41433.21819.44x418629315.519.34x4154.92011416 61839.623274x624433017.620.54x6179240.415.517.5 103460.83940.44x1030839819.822.54x10240.431417.520 164872.45058.34x1639451922.425.74x163143802022 2572103.87977.64x25476684
v1.0可编辑可修改 1 成都华远电器有限责任公司 yh电焊机用电缆标准 标称 截面 m㎡ 组成 根数/单线 直径mm 护套标 称厚度 mm 电缆最 大外经 mm 20℃时导体直流 电阻不大于ω/㎞ 电缆参考重 量㎏/㎞ 电缆截面最小 验收标准 m㎡镀锡不镀锡yhyhf 10322/148158 16513/223237 25798/319355 351121/423442 501596/591615 702220/808839 952997/10731111 1203811/13551401 1504773/16941749 1852590/20212073 v1.0可编辑可修改 2 成都华远电器有限责任公司 qvr电线标准 标称 截面 m㎡ 组成 根数/单线 直径mm 绝缘标 称厚度 mm 电线最
电流与导线横截面积成正比的关系,导线横截面积越大,允许通过的电流越大.同时,和导线电阻率有关,电阻 率越大,允许通过的电流越小,即和导体的材质有关.具体能通过多大的电流,一般>中都可查到. 运算的公式是:允许通过的电流=(电压*导线横截面积)/(导线电阻率*导线的长度) 塑料铜芯线载流量(安)表 导线截面(mm2)11.52.54610162535507095120 硬线bv根数/单根直径1/1.131/1.371/1.761/2.241/2.737/1.337/1.687/2.117/2.49 19/1.8119/2.1419/2.4937/2.01 软线bvr根数/单根直径7/0.437/0.5219/0.4119/0.5219/0.6419/0.8
导线粗细,与电流、功率的关系是什么? 电流与导线横截面积成正比的关系,导线横截面积越大,允许通过的电流越大.同 时,和导线电阻率有关,电阻率越大,允许通过的电流越小,即和导体的材质有关.具 体能通过多大的电流,一般>中都可查到.运算的公式是:允许通过的 电流=(电压*导线横截面积)/(导线电阻率*导线的长度) 导线的安全载流量跟它的材质有关,你要知道精确就必须查表。如果大概的话 可以这们估算: 铜导线,10平方以下的6-7a/平方。 10到20平方4-5a/平方。 20到50平方3-4a/平方. 50平方到350平方1-2a/平方 如果把各种材料制成长1米、横截面积1平方毫米的导线,在20℃时测量它们的电阻(称为这种材料的电 阻率)并进行比较,则银的电阻率最小,其次是按铜、铝、钨、铁、锰铜、镍铬合金的顺序,
一、一般铜导线载流量导线的安全载流量是根据所允许的线芯最高温度、冷却条件、敷设条件来确定的。一般铜导线 的安全载流量为5~8a/mm2,铝导线的安全载流量为3~5a/mm2。如:2.5mm2bvv铜导线安全载流量的推荐值 2.5×8a/mm2=20a4mm2bvv铜导线安全载流量的推荐值4×8a/mm2=32a 二、计算铜导线截面积利用铜导线的安全载流量的推荐值5~8a/mm2,计算出所选取铜导线截面积s的上下范围:s==0.125i~0.2i(mm2)s-----铜导线截面积(mm2)i-----负载电流(a) 三、功率计算一般负载(也可以成为用电器,如点灯、冰箱等等)分为两种,一种式电阻性负载,一种是电感性负载。 对于电阻性负载的计算公式:p=ui对于日光灯负载的计算公式:p=uicosф,其中日光灯
电缆规格外径与截面积对照表 yjv4+1yjv3+2 规格总外径总面积规格总外径总面积 5x615.81955x615.8195 5x1018.62705x1018.6270 5x1621.33605x1621.3360 4x25+1x1624.94903x25+2x1624450 4x35+1x1627.15803x35+2x1625.9530 4x50+1x2531.67803x50+2x2530.4725 4x70+1x3536.510503x70+2x3534.8950 4x95+1x5041.613603x95+2x5039.71250 4x120+1x7046.316703x120+2x7044.61560 4x150+1x7051.220603x15
职位:建筑方案设计师
擅长专业:土建 安装 装饰 市政 园林
文辑推荐
知识推荐
百科推荐